Class Ⅱ biological safety cabinet
✔Product specifications:
-
Biosafety cabinets are used in biological experiments to prevent damage from poisonous and harmful airborne particles during experimental operations, thereby protecting the safety of the operator and the environment.
-
Standard with a HEPA filter to protect products and the environment, SAFELOGICTM plenum leak prevention technology, an innovative, stable inflow speed system, featuring a BIOCASIONTM LCD screen and microcomputer control technology, especially for biological contamination in various high-risk experiments.
-
Meet the domestic YY0569-2005 BSC requirements and NSF / ANSI 49-2008, the European Union EN12469: 2000 BSC standard, to provide users with a satisfactory safety assurance.
-
IQ, OQ, PQ, and other related certification services.
-
CE certification. Three-year warranty period.
Ergonomic appearance, reasonable airflow design, multi-layer filtration system with a sophisticated microprocessor control, and reliable components.
Offer premium operator, product, and environmental protection with advanced technology.
Model | A2-1000G(D) | A2-1300G(D) | B2-1000G(D) | B2-1300G(D) |
|---|---|---|---|---|
Inflow velocity | 0.53m/s | 0.53m/s | 0.56m/s | 0.56m/s |
Down flow velocity | 0.35m/s | 0.35m/s | 0.35m/s | 0.35m/s |
Down flow velocity precision | ±0.015m/s | ±0.015m/s | ±0.015m/s | ±0.015m/s |
Noise level | ≤65(dB) | ≤65(dB) | ≤65(dB) | ≤65(dB) |
Vibration | ≤3μm | ≤3μm | ≤3μm | ≤3μm |
Light intensity | ≥650LX | ≥650LX | ≥650LX | ≥650LX |
Pressure difference range | 0~500Pa | 0~500Pa | 0~500Pa | 0~500Pa |
External dimensions(H*W*D) | 2210×1120×850mm | 2210×1420×850mm | 2210×1120×850mm | 2210×1420×850mm |
Dimension of working zone(H*W*D) | 700×1000×500mm | 700×1300×500mm | 700×1000×500mm | 700×1300×500mm |
Power | 300W | 350W | 300W | 350W |
Net weight | 175KG | 210KG | 175KG | 210KG |
Clean rating: ISO14644.1 CLASS 5 (US209E,CLASS 100)
HEPA: D series HEPA 99.99% (G series: ULPA 99.995%)
Operate environment: environment temp.10-30℃,relative humidity under 70%, no obvious vibration and dust

A2 Type:70% inner circulation, 30% exhaust
B2 Type:100% exhaust
Ergonomically design
1. Ergonomically angled front. Increase operating comfort, reduce work fatigue
2. Equipped with a splash electrical outlet. The Weight-Balance front window can move up and down freely.
3. INSIDE lighting system to provide the best illumination angle and brightness, reducing visual fatigue;
4. Front windows with explosion-proof, anti-ultraviolet tempered glass, to better protect the safety of the operator.